MTE Solutions Catalog
mtecorp.com Matrix ® AP Options Contactor Option 002: Contactor for capacitor disconnect • Includes NO/NC auxiliary contacts • Wired to customer terminal block • Pre-wired within enclosed part numbers • Requires 120V 50/60Hz power source Contactor Option 012: Contactor with control transformer (Only available for enclosed filters) • Option 002 including a 120 VAC control transformer Contactor Option 009: Contactor with adjustable pick up and drop out (Only available for enclosed filters) • Includes NO/NC auxiliary contacts • Includes a 120 VAC control transformer • Includes two current operated switches • Ability to adjust pick-up and drop current levels • Switches are preset at factory Pick-up is 35% of filter output current rating Drop out is 20% of filter output current rating Contactor Option 013: Filter bypass and capacitor contactor with control transformer (Only available for enclosed filters) • Includes NO/NC auxiliary contacts • Includes a 120 VAC control transformer • Pilot relay provided to limit inrush current • Jumper selection allows for single contact switching (Normal bypass control with capacitor removal) Option – 400: Standard NEMA 3R enclosure with optional rodent/serpent screen. • Provides intake exhaust air screens with (¼ x ¼) mesh • Not available on units 1600A (480V) and above Understanding the Matrix ® AP Part Number: Voltage Frequency Code A 208 – 240 Volts 60 Hz C 380 – 415 Volts 50 Hz D 480 Volts 60 Hz E 600 Volts 60 Hz F 690 Volts 50 Hz Optional Contactor Options 002 - Contactor for capacitor disconnect 012 - Contactor with control transformer 009 - Contactor with adjustable pick up and drop out 013 - F ilter bypass and capacitor contactor with control transformer Enclosure Type P = Open Magnetics (No Enclosure) G = General Purpose (NEMA 1/2) W = Weather (NEMA 3R) Current Rating 0006 is 6 Amps 0083 is 83 Amps 2300 is 2300 Amps Matrix ® AP How to properly size your filter MAP X _ _ _ _ X _ _ _ Harmonic Filters • Determine voltage and frequency requirements • Reference motor nameplate to determine motor HP or kW and Full Load Amps • Select filter based on Motor Full Load Amps Do not exceed filter's maximum current rating (amps) • Specify enclosure style Open (No enclosure) NEMA 1/2 (General Purpose Enclosure) NEMA 3R (Outdoor Enclosure) • Determine derating requirements Reference Performance Specifications table on previous page • Select desired options (if applicable) 25
Made with FlippingBook
RkJQdWJsaXNoZXIy MjgzMDI=