Ancor 2023

WIRE MANAGEMENT 44 ancorproducts.com Wire Seals • Made of Nylon 6/6 flame resistant, self extinguishing Buna-N form seal • All seals exceed NEMA Type 4X and Type 6 specs • Overlapping clamping spines allow for superior pull-out protection and resistance • Strain relief fittings are resistant to salt water, acids, alkalis, alcohol, oils and are non-corrosive for use in the marine environment • Good underwater to 300 feet / 91.4 m (150 PSIG) provided there is a liquid tight seal between body and housing • Provide low cost cable entries into panels and junction boxes • UL 94 v-0 Description For Use with Thread Size Cable Range Clearance Hole Body Length Thread Length Qty/ Pkg Part # Round Cable 18–10 AWG 3/8" NPT .08"–.24" 2–6 mm .68" .87" .59" 1 764998 Round Cable 10-2 AWG 1/2" NPT .20"-.47" 5–12 mm .83" 1.06" .51" 1 765000 Round or Flat Cable 4–1, 14/3-12/3 & 12/2–10/2 AWG 1/2" NPT .24"-.55" 6–14 mm .83" 1.10" .51" 1 765002 Round Cable 1–3/0 AWG 3/4" NPT .51"-.71" 13–18 mm 1.05" 1.22" .51" 1 765004 Round Cable 4/0 AWG 1" NPT .71"-.98" 18–25 mm 1.35" 1.53" .75" 1 765006 Flat Cable 14/3-12/3 & 10/2 1/2" NPT .31"-.56" 8–14 mm .83" 1.10" .51" 1 765010 Flat Cable 12/3 3/4" NPT .31"-.56" 8–14 mm 1.05" 1.22" .51" 1 765012 765010 765000 Grommets • Provide instant abrasion resistance to wires passing through panel holes • Flexible black vinyl makes installation simple Hole Size Inside Diameter Panel Width Qty/ Pkg Part # 3/8" 10 mm 1/4" 6 mm 3/32" 2 mm 5 760375 1/2" 13 mm 3/8" 10 mm 3/32" 2 mm 5 760500 1/4–3/4" Assortment Combo Pack (10 each of 1/4", 5/16", and 3/8", 5 each of 1/2", 11/16", and 3/4") 45 750000 Spiral Wrap & Split Loom • Permits flexible routing of cable harnesses • Provides abrasion protection for wire and cable • Allows lead outs at any point for greatest ease of installation • Split loom temperature range is -40°F to 275°F / -40°C to 135°C Marine Grade® Spiral Wrap Bundle Range Diameter Ft/Pkg Part # Min Max 1/4" 6 mm 10' 452251 3/16" 4.8 mm 2" 5 cm 3/8" 10 mm 10' 452381 5/16" 8 mm 3" 7.6 cm 100' 452385 1/2" 13 mm 10' 452501 25/64" 10 mm 4" 10.2 cm 100' 452505 3/4" 19 mm 10' 452751 3/4" 19 mm 5" 12.7 cm 100' 452755 1" 25 mm 5' 452900 1" 25 mm 7" 17.8 cm 100' 452905 Self-extinguishing Split Loom Diameter Ft/Pkg Part # 3/8" 10 mm 10' 453382 100' 453386 1/2" 13 mm 10' 453502 100' 453506 3/4" 19 mm 10' 453752 100' 453756 1" 25 mm 5' 453901 100' 453906 Wire Bundling per ABYC Guidelines ABYC states: “Conductors that may be exposed to physical damage shall be protected by loom, conduit, tape, raceways, or other equivalent protection. When AC and DC conductors are run together, the AC conductors shall be sheathed, bundled, or otherwise kept separate from the DC conductors. Loom used to cover conductors shall be self-extinguishing. The base product (or resin) shall be classified as V-2 or better, in accordance with UL 94, Tests For Flammability Of Plastic Materials.” TECH TIP

RkJQdWJsaXNoZXIy MjgzMDI=