2019 Mobile Catalog

102 CIRCUIT PROTECTION bluesea.com 285 Series Circuit Breakers Provides circuit protection for 25 to 150 Amp loads when switching and circuit protection are both required • Visible yellow reset lever shows open condition • Trip-free design cannot be held closed after trip • Drop in replacement for 185 Series Circuit Breakers • 3,000A AIC for medium battery banks Specifications Interrupting Capacity 3,000A @ 48V DC † Voltage Max. Operating 48V DC Temperature Min. Operating -40°C Temperature Max. Operating 85°C Type Thermal Class Type III – Switchable/Manual Reset – Trip Free Terminal Stud M6 (accepts 1/4" Ring Terminal) Terminal Stud Torque 50 in-lb (7.9 Nm) Mounting Hole Accepts 1/4" screw (M6) Regulatory Emarked Meets SAE J1171 external ignition protection requirements, † AIC ratings achieved using SAE J1625 IP67 – protected against immersion up to 1 meter for 30 minutes (see inside back cover) See page 174 for ABYC Interrupting Capacity Requirements. 7087 7187 bluesea.com/video 187 Series Circuit Breakers Provides circuit protection for 25 to 200 Amp loads when switching and circuit protection are both required • Self-trimming case eliminates need for mounting panels or trim bezels • Visible yellow reset lever shows open condition • Trip-free design cannot be held closed after trip • Large clearance around terminal studs accepts up to 1/0 AWG lugs • Recessed mounting holes for clean appearance • Robust 5/16"-18 terminals provide high torque connections • 5,000A AIC for large battery banks Specifications Interrupting Capacity 5,000A @ 12V DC 3,000A @ 24V DC 1,500A @ 42V DC Voltage Max. Operating 48V DC Temperature Min. Operating -40°C Temperature Max. Operating 85°C Type Thermal Class Type III – Switchable/Manual Reset – Trip Free Terminal Stud 5⁄16"-18 Terminal Stud Torque 75 in-lb max. Trip Time Delay Seebluesea.com Mounting Hole Accepts #10 (M5) Screw Regulatory Emarked Meets SAE J1171 external ignition protection requirements IP66 – protected against powerful water jets (see inside back cover) See page 174 for ABYC Interrupting Capacity Requirements. Panel Mount Part# Surface Mount Part# Amps 7035 7135 25A DC 7036 7136 30A DC 7038 7138 40A DC 7039 7139 50A DC 7040 7140 60A DC 7041 7141 70A DC 7042 7142 80A DC 7043 7143 90A DC 7044 7144 100A DC 7046 7146 120A DC 7048 7148 150A DC 7049 7149 200A DC 7044 7140 Panel Mount Part# Surface Mount Part# Amps 7080 7180 25A DC 7081 7181 30A DC 7082 7182 40A DC 7083 7183 50A DC 7084 7184 60A DC 7085 7185 70A DC 7086 7186 80A DC 7087 7187 100A DC 7088 7188 120A DC 7089 7189 150A DC

RkJQdWJsaXNoZXIy MjgzMDI=