29
toll free 800.307.6702 MASTERVOLT | mastervolt.com MARINCO | marinco.com ANCOR | ancorproducts.com
DOCK SIDE
BOAT SIDE
Item #
MALE PLUG
Attaches to dockside
receptacle or cordset
FEMALE CONNECTOR
Attaches to boat inlet
or cordset
G30
30A 125V
Locking
30A 125V
Locking w/
Sealing
Collar System
DOCK SIDE
BOAT SIDE
Item #
MALE PLUG
Attaches to dockside
receptacle or cordset
FEMALE CONNECTOR
Attaches to boat inlet
or cordset
1RPC
(30 amp)
30A 125V
Locking
30A 125V
Locking w/
Sealing
Collar System
1RPC50
(50 amp)
50A 125/250V
Locking
50A 125/250V
Locking w/
Sealing
Collar System
Connect:
Shore Power Adapters
Right Angle Adapters
Dockside 30A to 15A Adapter with GFI
G
W
G
W
G
W
G
W
• Provides safer hook-up to 30A dockside power
• Provides protection against harmful electric shock
• Reduces the possibility of fire
• Offers protection for up to 3 attached tools
• Corrosion resistant and rain-proof rated for outdoor use
• GFI trip level of 4–6 mA
• Can also be used for other outdoor, harsh environments such as
construction sites or wherever ground fault protection is desired.
Note: A Ground Fault Circuit Interrupter (GFCI) limits the duration
of an electrical shock to a period considered safe for healthy
people. It does not prevent electric shock. This device does not
protect against electric shock due to contact with both circuit
conductors or a fault in any wiring supplying this device.
G
X
Y
W
G
W
G
X
Y
W
NEMA
L5-30R
W
G
30A
125V
Locking
GalvanAlert
®
Shore Power Corrosion Detector
The world's only shore power corrosion detector with reverse
polarity indicator. GalvanAlert
®
easily attaches to your existing
30A shore power inlet and cordset to constantly monitor unsafe
corrosion activity or a reverse polarity condition.
• Can save you thousands of dollars in potential corrosive
damage to your boat
• Detects reverse polarity that can create a shock
or fire hazard
How does GalvanAlert
®
work?
GalvanAlert
®
incorporates sensor-based technology that monitors
unsafe galvanic or stray current corrosion flowing through the
green ground wire of your shore power system.
Why GalvanAlert
®
if I have a galvanic isolator?
Galvanic isolators only protect against galvanic action. They will
not block corrosion currents driven by more than 1.5 volts that can
be highly destructive to your boat. GalvanAlert
®
will detect such
currents so you can protect your boat in instances where galvanic
isolators do not.
G
W
NEMA
L5-30R
W
G
30A
125V
Locking
DOCK SIDE
BOAT SIDE
Item #
MALE PLUG
Attaches to dockside
receptacle or cordset
FEMALE CONNECTOR
Attaches to boat inlet
or cordset
199128
30A 125V
Locking
3–15A 125V
Straight Blade
Connect
|
Cordsets & Adapters