Background Image
Table of Contents Table of Contents
Previous Page  57 / 308 Next Page
Information
Show Menu
Previous Page 57 / 308 Next Page
Page Background

57

toll free 800.307.6702 MASTERVOLT | mastervolt.com MARINCO | marinco.com ANCOR | ancorproducts.com

Convert

|

Battery Chargers

Convert:

ChargeMaster Specifications – 12V

For detailed specifications, dimensional drawings, 3D files, images, certificates and manuals see

mastervolt.com/chargers.

ChargeMaster

12/25-3

ChargeMaster

12/35-3

ChargeMaster

12/50-3

ChargeMaster

12/70-3

ChargeMaster

12/100-3

44010250

44010350

44010500

44010700

44011000

12V

12V

12V

12V

12V

25A at 13.25V

35A at 14.4V

50A at 14.4V

70A at 14.4V

100A at 14.4V

3

3

3

3

3

25A

35A

50A

10A

10A

25A

35A

50A

10A

10A

50–250 Ah

70–350 Ah

100–500 Ah

140–700 Ah

200–1000 Ah

120/230V (90–265V) –

50/60Hz

120/230V (90–265V) –

50/60Hz

120/230V (90–265V) –

50/60Hz

120/230V (90–265V) –

50/60Hz

120/230V (90–265V) –

50/60Hz

2 mtr AC cable

connector strips

connector strips

connector strips

connector strips

yes

yes

yes

yes

yes

LED display

LED display

LED display

LCD display

LCD display

9.2"x5.2"x2.4"

234x132x60 mm

11.5"x8.3"x5.2"

291x210x131 mm

11.5"x8.3"x5.2"

291x210x131 mm

14.3"x11"x5.9"

362x277x150 mm

14.3"x11"x5.9"

362x277x150 mm

1,8 kg / 4 lbs

4 kg / 9 lbs

4 kg / 9 lbs

7 kg / 16 lbs

7 kg / 16 lbs

screw

with the supplied mounting bracket or 4x screw for wall mounting or 4x screw for floor installation

CE, ABYC A-31, SAE J1171/ISO 8846 ignition protected

IUoUo, automatic / 3-step for gel/AGM/wet/Lithium Ion

14.4V (8 hours)

14.4V (8 hours)

14.4V (8 hours)

14.4V (8 hours)

14.4V (8 hours)

14.25V (4 hours)

14.25V (4 hours)

14.25V (4 hours)

14.25V (4 hours)

14.25V (4 hours)

13.25V

13.25V

13.25V

13.25V

13.25V

13.8V

13.8V

13.8V

13.8V

13.8V

-30 mV/°C or -17 mV/°F -30 mV/°C or -17 mV/°F -30 mV/°C or -17 mV/°F -30 mV/°C or -17 mV/°F -30 mV/°C or -17 mV/°F

automatic

automatic

automatic

automatic

automatic

<2 mA

<5 mA

<5 mA

<5 mA

<5 mA

450 W

575 W

825 W

1200 W

1700 W

no

yes, through MasterBus yes, through MasterBus yes, through MasterBus yes, through MasterBus

0.98

0.98

0.98

0.98

0.98

-25°C–60°C, > 40 °C derating

-13°F–140°F, >77°F derating

-25°C–60°C, >40°C derating

-13°F–140°F, >104°F derating

maintenance vario fan to ensure optimized cooling

<52 dBA at 1 mtr

<52 dBA at 1 mtr

<52 dBA at 1 mtr

<52 dBA at 1 mtr

<52 dBA at 1 mtr

IP23

IP23

IP23

IP23

IP23

over temperature, over load, short circuit, high battery, low battery

yes

yes

yes

yes

yes

yes, using a Multipurpose Contact Output (Item #

77030500

)

Remote panel for reading the charge status of your battery charger, including error notifications.

Touch screen panel for reading charge status, current fold-back and/or Power Sharing setting.

MasterBus integrated battery monitor, with detailed information on the status of your batteries for a optimized charging process, incl. voltage, current, remaining time

and consumption capacity in percentage.

Smallest distribution model available. It connects up to four DC devices to the DC groups, such as a battery charger, inverter, alternators and solar panels. With the

included plug & play cable it can be easily connected to the MasterBus network.

Communication port between MasterBus and the USB port of your PC; makes possible reading and configuration of your MasterBus system on the PC when

combined with MasterView System software (free to download).

MasterBus controllable potential-free contact, with alarm notification on the onboard system (low voltage or no AC), replacement of the CSI alarm contact.