toll free 800.307.6702 MASTERVOLT | mastervolt.com MARINCO | marinco.com ANCOR | ancorproducts.com

Convert

|

Battery Chargers

Convert:

ChargeMaster Specifications – 24V

For detailed specifications, dimensional drawings, 3D files, images, certificates and manuals see

mastervolt.com/chargers.

ChargeMaster

24/40-3

ChargeMaster

24/60-3

ChargeMaster

24/80-3

ChargeMaster

24/100-3

44020400

44020600

44020800

44021000

24V

24V

24V

24V

40A at 28.8V

60A at 28.8V

80A at 28.8V

100A at 28.8V

3

3

3

3

10A

10A

10A

10A

10A

10A

10A

10A

80–400 Ah

120–600 Ah

160–800 Ah

200–1000 Ah

120/230V (90–265V) –

50/60Hz

120/230V (90–265V) –

50/60Hz

120/230V (90–265V) –

50/60Hz

120/230V (90–265V) –

50/60Hz

connector strips

connector strips

connector strips

connector strips

yes

yes

yes

yes

LCD display

LCD display

LCD display

LCD display

14.3"x11"x5.9"

362x277x150 mm

14.3"x11"x5.9"

362x277x150 mm

17"x11"x5.9"

432x277x150 mm

17"x11"x5.9"

432x277x150 mm

7 kg / 16 lbs

7 kg / 16 lbs

8 kg / 18 lbs

8 kg / 18 lbs

with the supplied mounting bracket or 4x screw for wall mounting or 4x screw for floor installation

CE, ABYC A-31, SAE J1171/ISO 8846 ignition protected

IUoUo, automatic / 3-step for gel/AGM/wet/Lithium Ion

28.8V (8 hours)

28.8V (8 hours)

28.8V (8 hours)

28.8V (8 hours)

28.5V (4 hours)

28.5V (4 hours)

28.5V (4 hours)

28.5V (4 hours)

26.5V

26.5V

26.5V

26.5V

27.6V

27.6V

27.6V

27.6V

-60 mV/°C or -33 mV/°F -60 mV/°C or -33 mV/°F -60 mV/°C or -33 mV/°F -60 mV/°C or -33 mV/°F

automatic

automatic

automatic

automatic

<5 mA

<5 mA

<5 mA

<5 mA

1400 W

2000 W

2700 W

3375 W

yes, through MasterBus yes, through MasterBus yes, through MasterBus yes, through MasterBus

0.98

0.98

0.98

0.98

-25°C–60°C, >40°C derating

-13°F–140°F, >104°F derating

-25°C–60°C, >40°C derating

-13°F–140°F, >104°F derating

maintenance free vario fan for optimal cooling

<52 dBA at 1 mtr

<52 dBA at 1 mtr

<52 dBA at 1 mtr

<52 dBA at 1 mtr

IP23

IP23

IP23

IP23

over temperature, over load, short circuit, high battery, low battery

yes

yes

yes

yes

yes, using a Multipurpose Contact Output

option

option

option

option

option

option

option

option

option

option

option

option

incl. voltage, current, remaining time and consumption capacity in percentage.

option

option

option

option

alternators and solar panels With the included plug & play cable it can be easily connected to the MasterBus network.

option

option

option

option

MasterBus system on the PC when combined with MasterView System software (free to download).

option

option

option

option

of the CSI alarm contact.