Monitoring

Solenoid Valve

The SA296COMP-12V is suitable

for countries where VR2.2 is not

approved. The CE approved

SA296COMP-12V can be

installed by an approved

gas installer using approved

components from within specific

markets. 12V or 24V options

available. Uses 1/4" BSP thread.

Note: A separate regulator will need

to be installed with the SA296 valves.

Item # SA296COMP-12V

12V

Item # SA296COMP-24V

24V

600-GD, 600-GDL, & FD-2 Specifications

Voltage (V DC)

10–32

Current (mA)

350 max.

Alarm Sensitivity 20% lower explosive limit

Current@Out (mA) 800 max.

Solenoid (mA)

700 pulse, 250 hold

600-GDRV has the sensor mounted in the

front facia creating a stand alone unit. The

unit is designed to be surface mounted at

the vessel’s lowest point.

600-GDRV

600-LPG

FD-2 is designed for an economic

in-dash installation. Supplied with sensor

(5 m cable) which is capable of

detecting combustible gases.

FD-2

600-GD will detect LPG, Petrol and CNG

fumes. Supplied with one sensor, with

an option for a second sensor, Item #

BL-SL-L output for remote alarm and

blower unit. 600-GD can be used on

12 or 24V systems.

600-GD

Same features as the 600-GD, with the

ability to switch a valve on. It contains a

unique “Pulse & Hold” circuit within the

detector. This allows the valve to be pulled

in at 12V and then once energized it will

step down to hold the valve in place. This

reduces power consumption and heat while

the gas is turned on.

600-LPG is a stand alone gas shut-off

system with no gas detection ability. For

12V systems order VR2.2 separately. For

24V systems order VR2.2-24V.

600-GDL

VR2.2

Solenoid Valve &

Regulator Kit

Compatible with 600-GDL

Gas Detector or 600-LPG.

Solenoid voltage: 12 V or 24 V

Gas outlet: 3/8 BSP

Gas inlet: POL Thread

Current draw: 800 mA

Current draw with GDL or PH-12V: 0.2 A

Regulator Flow Rate: 3 kPa.

Gas Detectors

The BEP™ Detectors use microprocessor control to ensure correct sensor

sensitivity. The Detectors have the capability to control two sensors which

detect both LPG and Petrol, with visual and audible alarms.

• Dual sensors for LPG and Petrol

• Visual and audible alarms; provision

for external alarm

• Automatic shut-off solenoid control

with pulse and hold circuit for low

power draw (600-GDL only)

• Self-testing

• Provision of bilge blower

• 2.4"x3.5"x0.7"

(67x88x17 mm)

BL-SL-L

One Sensor lead supplied (5 m) with

GD & GDL.

Second Sensor lead ordered separately

Manage:

Monitoring–Gas Detectors

Note: The VR2.2 may not comply in some countries, and

does not comply with USCG requirements. Please check

with your local gas installer. Not for sale in the USA.